Petroleum

  • HK-1010 Air Method Existent Gum Content Apparatus(3 holes), conforms to ASTM D381 standard. It is used to test existent gum content of aviation fuels, and the gum content of motor gasolines or other volatile distillates in their finished form, (including those containing alcohol and ether type oxygenates and deposit control additives) equips with 5 holes
  • The tester covers the use of Brookfield viscometers of appropriate torque for the determination of the low shear- rate viscosity of lubricants. The test is applied over the viscosity range of 500 to 900 000 mPa·s within a low temperature range appropriate to the capacity of the viscometer head.Mainly used for testing liquid lubricants, such as gear oils, torque and tractor fluids, and industrial and automotive hydraulic oils
  • HK-0059 Lubricating Oil Evaporation Loss Tester (NOACK Volatility Test) conforms to the ASTM D5800 Standard Test Method forEvaporation Loss of Lubricating Oils by the Noack Method, Procedure A, The evaporation loss is of particular importance in engine lubrication. Where high temperatures occur, portions of an oil can evaporate
  • HK-6538A Cold Cranking Simulator (CCS) viscosity apparatus conforms to the SAE J300 and ASTM 5293 Standard Test Method for Apparent Viscosity of Engine Oils and Base Stocks Between –5 and –35°C Using Cold-Cranking Simulator, which used for determining apparent viscosity of engine oils and base stocks by cold cranking simulator (CCS) at temperatures between –5 and –35°C at shear stresses of approximately 50 000 to 100 000 Pa and shear rates of approximately 105 to 104 s–1 for viscosities of approximately 900 to 25 000 mPa s. The range of an instrument is dependent on the instrument model and software version installed. Apparent Cranking Viscosity results by this method are related to engine-cranking characteristics of engine oils.
  • HK-1005 (1005A) Kinematic Viscosity Apparatus conforms the ASTM D445 StandardTest Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity). It is used to test the of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic viscosity, η, can be obtained by multiplying the kinematic viscosity, ν, by the density, ρ, of the liquid. under certain constant temperature. The range of kinematic viscosities covered by this apparatus method is from 0.2 to 300 000 mm2/s at all temperatures
  • HK-1004 Vacuum Distillation Apparatus conforms to the SH/T 0165 Standard Test Method for Distillation of Petroleum Products at Reduced Pressure. It is used for measuring at reduced pressures, of the range of boiling points for petroleum products and biodiesel that can be partially or completely vaporized at a maximum liquid temperature of 400°C.
  • HK-21929 Automatic Tag closed cup flash point apparatus conforms to the ASTM D56 Standard Test Method for Flash Point by Tag Closed Cup Tester , it is used For flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below 200°F (93°C) except cut-back asphalts, those liquids which tend to form a surface film under test conditions and materials which contain suspended solids. We use gas supply for the apparatus, gas circuit adopts stainless steel pipe, anti-aging, constant using. The instrument is highly automated with simple operation and accurate result. The instrument is equipped with two Danfoss compressors as cooling system, test lowest flash point temperature can reach minus 50 degree.
  • HK-1001B Fully Automatic Cleveland Open Cup Apparatus conforms to ASTM D92 Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It uses Cleceland Opent Cup method to test the flash point&fire point of lubricating oil and fuscous petroleum products.(Excluding fuel oil and petroleum products with open flash point lower than 79℃)
  • Automatic express analyzer LOIP LP-6749 developed for determination of cloud point (CP) and pour point (PP) of petroleum products according to ASTM D6749 (“Air pressure method") and ASTM D7683 (“Small test jar method"). LP-6749A1 determines CP and PP in one test cycle with high precision in compare with manual methods. Unique integrated cooling system provides cooling of samples up to -85°С in a short time without any external chiller.
  • Solid block bath apparatus to carry out up to five simultaneous tests for determining existent gum content in gasoline fuels by the jet Evaporation method according to ASTM D381, ISO 6246 and related specifications. Apparatus LOIP LP-381 is offered in two options of supply, without additional devices and together with compact diaphragm compressor. The compressor features very low noise level, high reliability, and ensures necessary air flow value.
  • New model of fully automated Cleveland flash point analyzer for determination of flash point temperature of petroleum products in a full accordance to ASTM D92, ISO 2592, IP36, GOST 4333 and other similar standards.
  • New model of fully automated Pensky-Martens flash point analyzer for determination of flash point temperature of petroleum products in a full accordance to ASTM D93 (A,B&C), ISO 2719, IP 34, GOST 6356 and other similar standards.